吉祥棋牌官网

当前位置:网站首页 > 新闻中心 > 行业资讯

N

新闻中心

  • 解决城市生活废水回用设备故障有哪些常用方法?
  • 本站编辑:四川国清源环保科技有限公司发布日期:2019-08-09 13:15 浏览次数:

生活废水处理是目前环境治理的重中之重,使用城市生活废水回用设备是快速有效的处理污水的有效途径,城市生活废水回用设备的选择也是很重要的。但是城市生活废水回用设备维护相对简单。尽管如此,为了延长设备的使用寿命,我们还应该建立一个定期的维护系统。今天,我们将为大家分享相关的城市生活废水回用设备常见故障。

1、异常水

检查接触氧化池,沉淀池,消毒池,污泥池通讯管道是否堵塞。

2、接触曝气池曝气不均匀

检查曝气扇出口阀是否处于正常位置,曝气头是否损坏。

3、生物膜接触效果不明显

检查接触氧化槽曝气是否均匀,第二沉淀池泵是否泵入池内。如果上述条件正常,可向池中加入适量的营养素。

4、出水水质达不到标准

接触氧化池曝气不均匀或长期停运(这必须重新培养生物膜),过量沉淀池污泥。消毒设备停止运行,消毒长时间不消毒。

5、自动控制出现故障

检查自动控制柜的电源是否正常,检查支撑升降泵和曝气风扇是否损坏。

       浙江国清环保科技有限公司提示您:设备就介绍到这里,欢迎有意者关注我们的网站,上面会随时更新动态,需要设备可以联系我们! 

Domestic wastewater treatment is the top priority of current environmental treatment. The use of municipal wastewater recycling equipment is an effective way to treat sewage quickly and effectively, and the selection of municipal wastewater recycling equipment is also very important. However, the maintenance of municipal wastewater recycling equipment is relatively simple. Nevertheless, in order to extend the service life of the equipment, we should also set up a regular maintenance system. Today, we are going to share with you the common failure of municipal wastewater recycling equipment.

1. Abnormal water

Check contact oxidation tank, sedimentation tank, disinfection tank, sludge tank communication pipeline is blocked.

2, contact aeration tank aeration is not uniform

Check whether the outlet valve of aerator fan is in normal position and whether the aerator head is damaged.

3. Biofilm contact effect is not obvious

Check whether the aeration of contact oxidation tank is uniform and whether the second sedimentation tank pump is pumped into the tank. If the above conditions are normal, an appropriate amount of nutrients can be added to the pool.

4. The effluent quality is not up to the standard

Contact oxidation tank aeration is not uniform or long-term shutdown (this must be re-cultured biofilm), excessive sedimentation tank sludge. Disinfecting equipment stops running, disinfecting for a long time.

5, automatic control failure

Check whether the power supply of the automatic control cabinet is normal, check whether the supporting lift pump and aeration fan are damaged.

Zhejiang guoqing environmental protection technology co., LTD tips you: the equipment is introduced here, welcome interested people to pay attention to our website, the above will be updated at any time, the need for equipment can contact us!


028-85358503(四川)

0571-86020907(总经理)

13881981010

成都市武侯区领事馆路8号万兴苑A座503室

友情链接:多盈彩票平台  乐发彩票  多盈彩票  乐发彩票网  多盈彩票  天天彩票官网  多盈彩票  

免责声明: 本站资料及图片来源互联网文章,本网不承担任何由内容信息所引起的争议和法律责任。所有作品版权归原创作者所有,与本站立场无关,如用户分享不慎侵犯了您的权益,请联系我们告知,我们将做删除处理!